What is Meant by Air Changes Per Hour?

Air changes per hour is a term used in the building and construction industry to describe the rate at which fresh air replaces stale air in a given space. The higher the number of air changes per hour, the fresher the air will be.

Building codes typically require a minimum number of air changes per hour in order to ensure adequate ventilation. Schools, hospitals, and other public buildings may have even higher requirements in order to protect the health of occupants. It

It is important to note that the air changes per hour rate is not the only factor that determines how fresh the air is in a space. The type of ventilation system, the use of filters, and the amount of outdoor air infiltration all play a role in determining the quality of air in a building.

Nevertheless, the air changes per hour rate is a good indicator of how well a ventilation system is working. A higher number of air changes per hour means that more fresh air is being supplied to the building.

Air Changes per Hour is also called the Air Exchange Rate, abbreviated to Abbreviated ACH or AC/HR.

How do I calculate air changes per hour?

The air changes per hour rate can be calculated by dividing the hourly ventilation rate by the volume of the space. For spaces with a perfectly mixed air or laminar flow, this will be equal to the number of times per hour that the space is exchanged by mechanical and natural ventilation.

Some common units of measurement for air changes per hour are liters per second (L/s), cubic meters per hour (m3/h), and cubic feet per minute (cfm).

How many times should air changes per hour?

The number of air changes per hour that is required in a given space depends on a variety of factors, including the type of building, the purpose of the building, and the weather conditions.

Building codes typically require a minimum number of air changes per hour, but many public buildings have higher requirements in order to protect the health of occupants. Schools and hospitals are two examples of buildings that often have high air change rates.

What is 10 air changes hourly?

Ten air changes per hour is the minimum number of air changes that is typically required in a building. This means that fresh air is being exchanged with stale air ten times per hour in order to maintain adequate ventilation. Many public buildings have higher requirements, however, and may have an air change rate of 20 or even 30.

What are good reasons for increasing the air changes hourly?

There are many reasons why a building owner might choose to increase the number of air changes per hour. Some common reasons include:

  • To improve the indoor air quality
  • To reduce the risk of mold and mildew growth
  • To control the spread of infection
  • To improve worker productivity

What is the HVAC Technician’s role in Air Changes per Hour?

The HVAC technician’s role in air changes per hour is to ensure that the building is meeting the minimum requirements for air changes. This may involve tuning the ventilation system, repairing leaks, and changing filters. The technician can also help to improve the air quality in a building by installing UV lamps and activated carbon filters. This knowledge is taught on a HVAC training program.

What are the ASHRAE recommended air changes per hour

ASHRAE  (previously called the American Society of Heating, Refrigerating and Air-Conditioning Engineers) recommends* that homes receive 0.35 air changes per hour but not less than 15 cubic feet of air per minute (cfm) per person, as the minimum ventilation rates in residential buildings in order to provide IAQ (Indoor Air Quality) that is acceptable to human occupants and that minimizes adverse health effects.

*Standard 62.2-2016, “Ventilation and Acceptable Indoor Air Quality in Residential Buildings”)