What is a Rooftop Unit (RTU) in an HVAC system?

A rooftop unit (RTU) is a type of HVAC system that is typically used in commercial and industrial buildings. RTUs are usually located on the roof of a building, and they work to provide heating, cooling, and ventilation for the interior spaces.

RTUs are typically larger and more powerful than other types of HVAC systems, and they are designed to handle the unique challenges of climate control for large buildings. RTUs can be custom-designed to meet the specific needs of a building, and they are often used in conjunction with other HVAC systems to provide comprehensive climate control.

How does an RTU unit work?

RTUs work by circulating air through the building using a system of ductwork. The air is first drawn into the unit by a large fan. The air is then passed through a series of filters to remove any particles or pollutants. Next, the air is cooled or heated as needed, and then it is distributed through the ductwork to the various rooms in the building.

What are the benefits of an RTU system?

An RTU system provides a number of benefits over other types of HVAC systems.

  • RTUs are very efficient at circulating air throughout a building, and they can be easily controlled to maintain a comfortable indoor environment.
  • Additionally, RTUs are typically less expensive to operate than other types of HVAC systems.

Rooftop unit components

The main components of an RTU are the blower, the compressor, the evaporator, and the condenser.

  1. The blower is responsible for drawing air into the unit, and the compressor circulates the refrigerant through the system.
  2. The evaporator cools the air, and the condenser releases heat from the system. An RTU also includes a number of controls and sensors that help to regulate the operation of the unit. These components include thermostats, pressure switches, and flow sensors.
  3. Thermostats are used to monitor and control the temperature of the air inside a building. Pressure switches are used to monitor the pressure of the refrigerant in the system, and flow sensors are used to regulate the flow of air through the

What is the difference between make up air unit and a rooftop unit?

Make-up air units (MAUs) and rooftop units (RTUs) are both types of HVAC systems that are used in commercial and industrial buildings. MAUs are typically used to provide fresh air to a building, while RTUs are used to provide heating, cooling, and ventilation.

MAUs are typically smaller than RTUs and they are not as powerful. MAUs also do not typically have the same features and options as RTUs. For example, MAUs may not have the ability to provide heating or cooling, and they may not be able to meet the specific needs of a building.

What is RTU in electrical?

RTU in electrical is an acronym for a remote terminal unit. A remote terminal unit is a type of computer that is used to remotely control and monitor devices or systems. RTUs are typically used in industrial and commercial applications, and they can be used to control anything from simple lights to complex machinery.

RTUs are often used in conjunction with SCADA systems, and they can be used to monitor and control processes that are located far away from the RTU itself.

For example, an RTU could be used to remotely monitor and control the operations of a factory in another country.

RTU HVAC cost

RTU HVAC systems can vary in cost depending on the size and features of the unit. RTUs typically range in cost from $2,000 to $20,000. The cost of an RTU will also depend on the specific needs of the building, and the climate conditions that the RTU will be used.

For example, an RTU that is designed for a hot and humid climate will typically be more expensive than an RTU that is designed for a cooler climate.